Kadriye Memiç Sancar1, Gamze Babür Güler1, Enes Arslan1, Ender Öner1, Ekrem Güler2, Mustafa Yıldız1

1Department of Cardiology, Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Istanbul, Turkey
2Department of Cardiology, Faculty of Medicine, University of Istanbul Medipol, Istanbul, Turkey

Keywords: Pacemaker lead; transesophageal echocardiography; tricuspid valve

Abstract

Tricuspid stenosis occurs after the implantation of a ventricular pacemaker lead and is a rare complication. An inflammatory response is stimulated when the pacemaker leads are passing through the tricuspid valve which leads to fibrosis in the long-term. In our case report, we aim to present a patient with asymptomatic multiple pacemaker lead- related tricuspid stenosis and with a history of severe COVID-19 pneumonia.

Introduction

Tricuspid stenosis (TS) is a rare complication that may occur after the implantation of a ventricular pacemaker electrode(1). An inflammatory response (inflammation) occurs when the pacemaker leads are passing through the tricuspid valve (TV), and this condition can lead to fibrosis in the long term(2). A wide array of studies has reported cardiovascular (CV) complications in COVID-19 patients(3,4). We aimed to present a patient who had a history of prolonged hospitalization due to COVID-19 pneumonia and was referred to our cardiology clinic and was detected to have multiple looped pacemaker leads through radiological examination, a condition as severe as COVID-19 pneumonia.

Case Report

A 68-year-old female patient was referred to our clinic for further evaluation after having been diagnosed with TS in another outpatient clinic. Her COVID-19 PCR test was negative. The patient had lately stayed in the hospital for 20 days due to severe COVID-19 pneumonia (Figure 1). She had a pacemaker lead implanted 20 years ago due to a complete atrioventricular (AV) block. In our clinic, her examination findings were as follows: her pulse was regular with a heart rate of 85 bpm, her blood pressure was 128/79 mmHg, and her oxygen saturation was 95%. She had neither any complaints nor signs of hepatomegaly, lower extremity edema, and jugular venous distension. Newly performed chest radiography suggested the presence of a loop caused by ventricular lead at the TV level and the existing leads of the former pace implantation (Figure 2). The echocardiographic evaluation reported normal ranges for size and function of the right and left ventricles. A transthoracic echocardiogram identified a TS with a mean gradient of 8 mmHg and a maximum gradient of 16 mmHg at the normal resting heart rate (Figure 3). Pressure half time was measured as 154 milliseconds. Inferior vena cava size was normal with normal inspiratory collapse. The TV was limitedly evaluated in the transesophageal echocardiography due to the calcified leads which filled the right atrium (RA) (Figure 4). The TV posterior leaflet was thicker and had a restricted leaflet opening. Leads were preventing tricuspid inflow and caused possible adhesions and retraction of the TV. TS was found to be associated with both multiple lead-induced occlusion and lead-induced fibrosis of the valve. The patient was showing no clinical and echocardiographic signs of heart failure and having no suspected infective endocarditis during her consultation, thus the Heart Team planned the medical treatment and decided to closely monitor the patient.




Discussion

A wide spectrum of complications, including acute coronary syndrome, myocarditis, acute-onset heart failure, arrhythmias, and cardiac arrest may arise in the presence of COVID-19 infection(3,4).

Damage to TV leaflets or subvalvular structures may be observed due to lead implantation or manipulation(1). These lead-related injuries include laceration, leaflet perforation, and transection of papillary muscles or chordae tendineae(2). Imaging techniques are of vital importance in the evaluation of the relationship between the TV and the pacemaker lead or subvalvular structures.

Tricuspid regurgitation (TR) is the most common TV disease which occurs due to lead implants(5). The lead passes through the TV or directly interacts with chordae tendineae and impairs leaflet coaptation. Together with the mechanical impact, the long-time interaction between the leaflet and the leads damages the mobility and coaptation of the leaflet causing inflammation and fibrosis(2).

Lead-related TS is not common in the literature (1). The clinical course is mostly asymptomatic in the long-term, and the diagnosis is delayed, thus the patient presents with right heart failure(6). In the literature, lead-related TS was reported to be treated with surgical replacement, surgical valvuloplasty, or percutaneous balloon valvuloplasty(7). Uijlings et al., presented a surgical treatment of a pace-related TS in a patient presenting with right heart failure(7). In our country, Cetiner et al., performed a successful percutaneous valvuloplasty to a severe symptomatic TS developed after endocardial VVI pacemaker lead implantation in an 18-year-old(8). However, corrective interventions are highly challenging in lead-associated TV damage because of the ventricular lead position across the TV.

In conclusion, our case is significant as the patient did not have any findings that suggest right heart failure despite the pacemaker lead-related TS and prior COVID-19 pneumonia. Although radiologically revealed COVID-19 pneumonia and multiple leads were worrisome in the first place, the asymptomatic condition of our patient and the possible risks of invasive procedures were the main determining factors in the treatment plan of our patient.

Peer Review

Externally peer-reviewed.

Author Contributions

Concept/Design - KS, GG; Analysis/Interpretation - EA, EO; Data Collection - EA, EO; Writing - KS; Critical Revision - GG, MY; Statistical Analysis - MY; Final Approval - All of Authors.

Conflict of Interest

The authors have no conflicts of interest to declare.

Financial Disclosure

The authors declared that this study has received no financial support.

References

  1. Husain A, Raja FT, Fatallah A, Fadel B, Alsanei A, Raja FT, et al. Tricuspid stenosis: an emerging disease in cardiac implantable electronic devices era. Case report and literature review. J Cardiol Cases 2017;15:190-3. [Crossref]
  2. Chang JD, Manning WJ, Ebrille E, Zimetbaum PJ. Tricuspid valve dysfunction following pacemaker or cardioverter-defibrillator implantation. J Am Coll Cardiol 2017;69:2331-41. [Crossref]
  3. Shi S, Qin M, Shen B, Cai Y, Liu T, Yang F, et al. Association of cardiac injury with mortality in hospitalized patients with COVID-19 in Wuhan, China. JAMA Cardiol 2020;5:802-10. [Crossref]
  4. Xu Z, Shi L, Wang Y, Zhang J, Huang L, Zhang J, et al. Pathological findings of COVID-19 associated with acute respiratory distress syndrome. Lancet Respir Med 2020;8:420-2. [Crossref]
  5. Polewczyk A, Kutarski A, Tomaszewski A, Brzozowski W, Czajkowski M, Polewczyk M, et al. Lead dependent tricuspid dysfunction: analysis of the mechanism and management in patients referred for transvenous lead extraction. Cardiol J 2013;20:402-10. [Crossref]
  6. Krishnan A, Moulick A, Sinha P, et al. Severe tricuspid valve stenosis secondary to pacemaker leads presenting as ascites and liver dysfunction: a complex problem requiring a multidisciplinary therapeutic approach. J Interv Card Electrophysiol 2009; 24: 71-75. [Crossref]
  7. Uijlings R, Kluin J, Salomonsz R, Burgmans M, Cramer MJ. Pacemaker lead-induced severe tricuspid valve stenosis. Circ Heart Fail 2010;3:465- 7. [Crossref]
  8. Çetiner N, Baştuhan IY, Özyiğit T, Mutluer FO, Çeliker A. Pacemaker lead-induced tricuspid stenosis treated with percutaneous valvotomy. Turk J Pediatr 2020;62:681-4. [Crossref]

Figure and Tables